. PLC: D0-06AR Card: F0-08ADH-1 Format: BCD Logic: Setup LD K0800 OUT V710 LDA O1552 OUT V711 Analog Input Channel 4 LDD V1560 (RAW INPUT) SUBD 13107 (OFFSET) BIN BTOR DIVR R52428 MULR 105. 00 8-channel analog voltage input module, high resolution ANALOG 0–10V F0-08ADH- 2 IN CH1 CH2 CH3 CH4 COM CH5 CH6 CH7 CH8 COM COM +24V 0V 24VDC Power Supply 0VDC +24VDC COM COM COM 4-wire Voltage Transmitter AC or DC CH5 3-wire Voltage + Transmitter CH3 CH1 CH8 Shield, Ch. 5 Voltage Transmitter. F0-08ADH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-04DAH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 *Direct Logic F0-08ADH-1 AI Call for Price: 01711 233784, 01918 434241 Request for Quotation: [email protected] lbs Estimated Value - 518. End of Search Dialog. : ZL-RTB20 Cable Part No: ZL-D0-CBL13_ Shipping Weight: 1. . The F0-08ADH-2 has jumper selectable input ranges of either 0-5 VDC or 0-10 VDC. DL06 Micro PLC User. 42” x 2. Re-Order Number. Rev. . 6. 5m, -1 = 1m, -2 = 2m1 1Note: Cable part number denotes. 5 mA Off to On Response 2 ms, Typ. Are you in EU? Call: +44 1782 576800. The DL205 modular PLC is a versatile rack-based solution that. com DL06, DL05, D0-OPTIONS-M User manual • DL06, DL05, D0-OPTIONS-M PDF manual download and more Automationdirect. One of the functions of the 06 is monitor current of the pumps with a five stage overload shutdown by time/current. 2. F0-04AD-1 8 See Note 2 F0-04AD-2 8 F0-08ADH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog. 8 channel analog input, voltage, 16 bit resolution. Resolution. • Analog inputs can be used as process variables for the four (4) PID loopsThe F0-08ADH-1 eight-channel current input module operates with a 0-20 mA input range. Note: ZIPLink Connector Module specifications follow theThe F0-08ADH-1 eight-channel current input module operates with a 0-20 mA input range. 10A < 1ms. 8mm x 51. DirectLOGIC programmable logic controller products range from micro-sized fixed I/O units to modular systems with thousands of I/O. Results 1 - 13 of 13. CSS ErrorWiring diagram and specifications Power input wiring D0-06DD1 Specifications AC Power Supply Voltage Range Specifications Number of Input Pts. 1 1 1 1 1 1 9 8 7 6 5 4 3 2 1 0 5 4 3 2 1 0 For example, assume the F0–08ADH–1 is. This will work if you have a temperature sensor that will output a 0-20mA signal. F0-08ADH-2 8-channel analog voltage input module, high resolution ANALOG 0–10V F0-08ADH-2 IN CH1 CH2 CH3 CH4 COM CH5 CH6 CH7 CH8 COM COM +24V 0V 24VDC Power Supply 0VDC +24VDC COM COM COM. . Be the first to review this product . DL05/06 PLC Fixed I/O ZIPLink SelectorF0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. Analog Input Module. • Full 16-bit resolution. 00 8-channel analog voltage output module, high resolution Output Specifications Number of Channels Output Range Resolution Output Type PLC Data. Part: F0-08ADH-2. It’s that easy. 205 Analog and Temperature Inputs with PLC CPU . Shop Categories Shop over 1 million products. F0-2AD2DA-2 2 entradas y 2 salidas analógicas de voltaje. 8 VDC Common Mode Rejection 100dB min. 자동화제어 및 검사계측 부품&장비 공급F0-08ADH-2 F0-04DAH-1 F0-08DAH-1 F0-04DAH-2 F0-08DAH-2 F0-2AD2DA-2 8 These modules are not supported by the ZIPLink F0-4AD2DA-1 wiring system. F0-04AD-1 $84. The Automation Direct Facts Engineering Koyo F0-08ADH-2 is an optional analog voltage input module. 2 COM CH1 CH3 CH2 CH4 Output Specifications Number of Channels 4 Output Range 0-10VDC Resolution 16-bit, 152µV/bit Output Type Voltage sourcing/ sinking at 5mA max. Wiring Solutions Solution 1: DirectLOGIC I/O Modules to ZIPLink Connector Modules When looking for quick and easy I/O-to-field termination, a ZIPLink connector module used in conjunction with a prewired ZIPLink cable, consisting of an I/O terminal block at. DL06 Special V-memory Locations. representative photo click to zoom Weight: 0. 5 Kbps 3278 1000 32786 10000 500 Kbps 1311 400 13114 4000 1. Select a ZIPLink module. . Search for Questions, Answers & Knowledge Articles. Terminal Block Specifications. F0-08ADH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-08ADH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-04DAH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. Please call or email us with your request. This unit is one of many optional modules. Quantity: Add to Cart. 8-channel analog input module for DL05/06 PLCs, range: 0-5V or 0-10V voltage input at 16-bit resolution. . F0-08ADH-2 reading outside 16 bit range - AutomationDirect. Specifications of the F0-08ADH-2: 8 Analog inputs; Range: 0-5V, 0-10V; 16-bit resolution; Removable terminal block;NOTE: The F0–08ADH–1 analog module cannot sense the loss of analog input signals in 0–20mA loops. The DL05/06’s analog capabilities are a great fit for a variety of applications at a fraction of the competition's price. Setting the Module Jumpers. 10 or newer to solve this problem. Step 2 Locate Connector Module Type. T1F-16DA-2 FC-T1 F0-08DAH-2 F0-08DAH-1 F0-08ADH-2 F0-08ADH-1 F0-04DAH-2 F0-04DAH-1 P3-01AC F2-8AD4DA-1 F2-8AD4DA-2 F2-CP128. SKU: F0-08ADH-2 Categories: DirectLogic Series, DL05/06 Analog I/O Modules, Programmable Controllers. Be the first to review this product . F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-PSCM 530mA none H0-CTRIO2 250mA none H0. The DirectLogic option modules include 16-bit high-resolution analog modules designed for DL05 and DL06 PLCs. 00 4-channel analog voltage input module F0-04AD-2 Input Specifications Number of Channels 4, single ended (one common) Input Range 0 to 5 VDC or 0 to 10 VDC (jumper selectable) Resolution 12 bit (1 in 4096) Step Response 10. ×Sorry to interrupt. 5 ms Maximum OFF Current 0. Chapter 4: F0-08ADH-1 8-Ch. Review these specifications to make sure the module meets your application requirements. . famaga. F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-CTRIO2 250mA none H0-ECOM100 300mA none F0. F0-04AD-1 8 See Note 2 F0-04AD-2 8 F0-08ADH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13. LoginF0-08ADH-1 <---> 8-channel analog current input module, high resolution 2-wire 4–20mA Transmitter 24VDC Power Supply 0VDC +24VDC COM COM COM 4-20mA Transmitter Shield, Ch. CLICK CPU Discrete Input Module ZIPLink Selector I/O Module. Notify me when the price drops . 0 m. The F0-08ADH-2 has jumper selectable input ranges of either 0-5 Vdc or 0-10 Vdc The four-channel F0-04DAH-1 and eight-channel F0-08DAH-1 current output modules provide a 4-20 mA output range, while the four-channel F0-04DAH-2 and the eight. . 5 Voltage Transmitter. SEE NOTE 1 SHIELD CONNECTED TO SIGNAL SOURCE COMMON. Programmable Controllers (PLC) HMI (Operator Interface)US $12. 1 Caution: The F0-04TRS relay outputs are derated not to exceed 2A per point when used with the ZIPLink wiring system. F0-4AD2DA-2 F0-04RTD Matched Only These modules are not supported by the ZIPLink F0-04THM wiring system. 20W. F0-04AD-1 8 See Note 2 F0-04AD-2 8 F0-08ADH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog. F hapter F00D hannel nalo urrent nput Module Specifications The F0-08ADH-1 Analog Input module offers the following features: • The DL05 and DL06 will read all eight channels in one scan. 03” (44. F0-4AD2DA-2 F0-04RTD Matched Only These modules are not supported by the ZIPLink F0-04THM wiring system. FACTS ENGINEERING L L C GUIDE INFORMATION Need More Information? Looking for Guide Information documents and more? Product iQ offers. 1 degree C/F resolution. . It’s that easy. F0-08ADH-1 <---> 8-channel analog current input module, high resolution 2-wire 4–20mA Transmitter 24VDC Power SupplyDimensions (WxHxD) 1. • The removable terminal block simplifies module replacement. 288. 자동화제어 및 검사계측 부품, 장비 공급Comprar DirectLOGIC F0-08ADH-1 organizamos su pedido Organizamos su pedido por todo de Colombia. 6 AC outputs, 0. Multiple model numbers may indicate different products, different components within the products or both. 3. V2000. F0-08DAH-2 - 8-channel analog output module, range: 0-10V voltage output. Select a ZIPLink module. † The removable terminal block simplifies module replacement. This unit is one of many optional modules compatible with DirectLogic 05 and DirectLogic 06 series programmable controllers. F0-08ADH-2 - 8-channel analog input module, range: 0-5V or 0-10V voltage input. LoginThe F0-08ADH-1 is a 0-20mA input and the reading in the PLC will be a value between 0 and 65535 proportional to the mA input. 08 mm) 28-16AWG Solid or Stranded Conductor;F0-04AD-2 Input Specifications Number of Channels 4, single ended (one common) Input Range 0 to 5VDC or 0 to 10VDC (jumper selectable) Resolution 12 bit (1 in 4096). F0-2AD2DA-2 $264. DL05/06 PLC Fixed I/O ZIPLink SelectorF0-04DAH-1 F0-04DAH-2 F0-08ADH-1 F0-08ADH-2 F0-08DAH-1 F0-08DAH-2 [Fixed problems] - Change the pointer method setup for analog modules in RUN mode caused the DL05 read wrong analog values. F0-04AD-2 $204. End of Search Dialog. Two outputs can be used as a. Results 1 - 13 of 13. Specifications. $467. 4 mA. Display #. 9. Need help selecting a PLC family? The F0-08ADH-2 Analog Input module offers the following features: The DL05 and DL06 will read all eight channels in one scan. F0-04AD-2 $204. Analog Current Input. The Automation Direct Facts Engineering Koyo F0-08ADH-2 is an optional analog voltage input module. . It’s that easy. qxd. 00 4-channel analog voltage input module F0-04AD-2 Input Specifications Number of Channels 4, single ended (one common) Input Range 0 to 5VDC or 0 to 10VDC (jumper selectable) Resolution 12 bit (1 in 4096) Step Response 10. F0-08ADH-2 CCHAPTERHAPTER 8-C AN ALOG HANNEL. Company The Company that holds the listing with UL. This version of Internet Explorer is either no longer supported by Microsoft , or is obsolete and some features of our store may no longer be supported. 0 m, or -2 = 2. com. F0-08ADH-2 - 8-channel analog input module, range: 0-5V or 0-10V voltage input. Company The Company that holds the listing with UL. . . 00 8-channel analog current input module, high resolution 2-wire 4–20mA Transmitter 24VDC Power Supply 0VDC +24VDC COM COM COM 4-20mA Transmitter Shield, Ch. . @ 60 C F0-4AD2DA-1 <---> 4-channel analog current input and 2-channel analog current output module * One count in the specification table is equal to one least significant bit of the analog. 자동화제어 및 검사계측 부품, 장비 공급자동화제어 및 검사계측 부품&장비 공급The F0-08ADH-2 Analog Input module offers the following features: † The DL05 and DL06 will read all eight channels in one scan. DL05/06 I/O Option Modules . 1 Caution: The F0-04TRS relay outputs are derated not to exceed 2A per point when used with the ZIPLink wiring system. The F0-08ADH-2 has jumper-selectable input ranges of 0 to 5 Vdc or 0 to 10 Vdc. For mental health services, a. DL05/06 Option Modules User Manual; 7th Ed. F0-04AD-1 $84. . F0-08ADH-2 8 channel analog input, voltage, 16 bit resolution € 322,90 each: Add to cart More info: F0-04DAH-1 4 channel analog output, current, 16 bit resolution. F0-08ADH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-04DAH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-08DAH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-04DAH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-08DAH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 * F0-2AD2DA-2 8 Feedthrough-. Add to Cart. 2. 6. 1-F0-08NA-1 8PT. F0-08ADH-2 có dải đầu vào nhảy cóc 0-5 Vdc hoặc 0-10 Vdc. 66 up to 167 I was able to get the sample programming using BCD on page 17 of the manual to work. 13. Slot No. Search for Questions, Answers & Knowledge Articles. All eight channels. Binary Example. 5A/point. LoginChapter 5 - F0-04AD-2, 4-Channel Analog Voltage Input. 5m, -1 = 1m, -2 = 2m1 1Note: Cable part number denotes. 12-24VDC. 1 2. Category Selection. 0mA @ 132VAC Input Impedance 33Kq On Voltage Level 80VAC minimum Off Voltage Level 20VAC maximum Minimum On Current 2. T1F-16DA-2 FC-T1 F0-08DAH-2 F0-08DAH-1 F0-08ADH-2 F0-08ADH-1 F0-04DAH-2 F0-04DAH-1 P3-01AC F2-8AD4DA-1 F2-8AD4DA-2 F2-CP128. F0-08DAH-2 $314. 5500. FACTS ENGINEERING L L C GUIDE INFORMATION Need More Information? Looking for Guide Information documents and more? Product iQ offers. contaminación 1 de acuerdo a EN61131-2) Vibración MIL STD 810C 514. 74” x 3. Order international: +1 609. 112. 8-channel analog input module for DL05/06 PLCs, range: 0-5V or 0-10V voltage input at 16-bit resolution. Simply plug one end of a ZIPLink pre-wired terminal block cable into your I/O module and the other end into a ZIPLink connector module. Monitor for counts less than ~13107 (4mA@16bit resolution) F0-08ADH-2 . The removable terminal block simplifies module replacement. Find great deals on eBay for f0-08adh-2. F0-04THM 4 entradas de termopar. € 484,00. € 484,00. . followed by N or T 3 or A-1. Radwell is not an authorized distributor, reseller or representative of the products featured on this website. 0 VDC Minimum ON Current 3. 4%. 9393. 12/24VDC. SKU: F0-04AD-2 F0-04AD-2 . Quick Selection Guide. Add to quote request. ×F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. . DL05/06 PLC Fixed I/O ZIPLink SelectorF0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-CTRIO2 250mA none H0-ECOM100 300mA none F0. From simple. F0-08DAH-2 $314. Freight shipments, FedEx ground and customer pickup deadline is 11:00AM ET. d0-16td1 se-sw5u-p p3-8ad4da-1 t1f-08da-1 d2-anlg-m d2ctrint h2-erm se-sw9u-st t1f-16ad-2 f0-cp128 (a) t1k-08tr d2-12tr h0-ctrio2 zl-cdm-rj12 d3-08nd2 zl-cbl40 followed by -s,. 2 CH2 CH4 Output Specifications Number of Channels 4 Output Range 4-20 mA Resolution 16-bit, . F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. Module Specifications. F0-04RTD 4 entradas de temperatura con RTD. Typical User Wiring Internal Module Circuitry CH1 ADC 3-wire Voltage. 6 DC outputs (sinking), 1. DL05/06 PLC Fixed I/O ZIPLink Selector計 不具合修正2件 Version 1. T1F-16DA-2 FC-T1 F0-08DAH-2 F0-08DAH-1 F0-08ADH-2 F0-08ADH-1 F0-04DAH-2 F0-04DAH-1 P3-01AC F2-8AD4DA-1 F2. . 0 VDC Off Voltage Level < 2. 5 Mbps 655 200 6557 2000 3 Mbps 327 100 3270 1000 6 Mbps 327 100 3270 1000 12 Mbps 327 100 3270 1000 Recommended Cables Siemens 6XV1 830 0AH10 Belden 3079A ERNI ERbic connectors Part No. @ 60 C 125 load 0. Find a location near you. F0-08ADH-2 PLCs/Machine Control from AUTOMATION DIRECT 2-Year Warranty, Radwell Repairs - DIRECTLOGIC DL05/06 ANALOG INPUT MODULE, 8. F0-08ADH-2 F0-04DAH-1 F0-08DAH-1 F0-04DAH-2 F0-08DAH-2 F0-2AD2DA-2 8 These modules are not supported by the ZIPLink F0-4AD2DA-1 wiring system. (Feedthrough Module, Fuse Module, etc. Inputs per module. F Analog Modules Part Number Description F0-04AD-1 4-Channel Analog Input, Current F0-04AD-2 4-Channel Analog Input, Voltage F0-08ADH-1 8-Channel High-Resolution Analog Input, Current F0-08ADH-2 8-Channel High-Resolution Analog Input, Voltage F0-04DAH-1 4. DL05/06 I/O Option Modules F0-08NA-1 $51. Select a corresponding ZIPLink cable. DL06 Data Formatting. . F0-08ADH-1 <---> 8-channel analog current input module, high resolution 2-wire 4–20mA Transmitter 24VDC Power SupplyDimensions (WxHxD) 1. Multiply by 100 early on will. Add to Wish List Add to Compare. Quick Order. The Automation Direct Facts Engineering Koyo F0-08DAH-2 is an eight channel analog voltage output module. ZL-RTB-DB09 ZL-RTB-DB15 ZL-RTB. $388. 00 4-channel analog current input module F0-04AD-1 Input Specifications Number of Channels 4, single ended (one common) Input Range 0 to 20mA or 4 to 20mA (jumper selectable) Resolution 12 bit (1 in 4096) Step Response 25. 자동화제어 및 검사계측 부품, 장비 공급Question about Analog Input with Read Number Calculation - AutomationDirect. com. Add to cart More info. F0-4AD2DA-1 8 ZL-D0-CBL8# F0-4AD2DA-2 8 ZL-D0-CBL8# F0-04RTD** F0-04THM** Step 1 Locate the I/O Module part number. F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-CTRIO2 250mA none H0-ECOM100 300mA none F0. Some of the module's features are the DL05 and DL06 series' ability to read all eight channels in a single scan, being isolated from the PLC power supply logic side, a removable terminal block helping ease the replacement of the module, the ability to process variable for the four and eight PID loops in the. If you need a specific firmware or series relating to F0-08ADH-1, we probably have it. . DirectLOGIC DL05/06 analog input module, 8-channel, voltage, 16-bit, input voltage signal range (s) of 0-5 VDC, 0-10 VDC, external 24 VDC required. Specifications of the F0-08ADH-2: 8 Analog inputs; Range: 0-5V, 0-10V; 16-bit resolution; Removable terminal block;Ch. End of Search Dialoge2-68 Programmable Controllers 1-800-633-0405 Cut PLC wiring time to minutes instead of hours The ZIPLink wiring system eliminates the normally tedious process of wiring PLC I/O to terminal blocks. Specifically, this module converts digital signals from the PLC into outgoing analog voltage signals. In stock items ship in 2-5 days to ensure Radwell's Quality Assurance inspections. A 0mA signal would be 0 and a 20mA signal. LSB. . 5 ms ON to OFF Response 2–8 ms, Typical 4ms OFF to ON Response 2–8 ms, Typical 4ms Commons 1 (4 points/common) D0-07CDR Output Specifications Number of Outputs 3 Output Voltage. 1mm x 86. vn Model. F0-4AD2DA-2 4 entradas y 2 salidas analógicas de voltaje. A Date Issued: 02/21/2023 Revision: Original This Product Advisory is related to the improper operation of the F0-08ADH-2 module when 24VDC is not present on the module. DL06 Version 2. 1 ms On to Off Response 2 ms, Typ. Select a corresponding ZIPLink cable. F0-04AD-1 50mA none F0-04AD-2 75mA none F0-08ADH-1 25mA 25mA F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 Power Source For the latest prices, please check AutomationDirect. Order international: +1 609. Display #. 98. Screwdriver Size (Slotted) Screw Size. Number of Positions. Contact Info 57 Marinda Ave, Clubview, Centurion, Gauteng, South Africa. The F0-08ADH-2 Analog Input module offers the following features: • The DL05 and DL06 will read all eight channels in one scan. Specifications. F0-08ADH1. com online manualsView online (7 pages) or download PDF (399 KB) Automation Direct DL05 Getting Started • DL05 PDF manual download and more Automation Direct online manualsF0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-PSCM 530mA none H0-ECOM 250mA H0-CTRIO 250mA. Resolution. Broken Transmitter / Burnout Detection : Indication with PLC CPU (Pointer Method) (Manual References are D2-ANLG-M 7. F2-02DA-2L F0-08ADH-1 ZL followed by -D24 followed by -CBL40 followed by with or without, -1, -2, X, -1X,. Need help selecting a. ×Sorry to interrupt. F0-08ADH-2 có dải đầu vào nhảy cóc 0-5 Vdc hoặc 0-10 Vdc. Please call or email us with your request. 8 channel analog input, current, 16 bit resolution. Model Number(s) Model numbers included in the listing. Ch. . F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. 자동화제어 및 검사계측 부품&장비 공급F0-08ADH-2 F0-04DAH-1 F0-08DAH-1 F0-04DAH-2 F0-08DAH-2 F0-2AD2DA-2 8 These modules are not supported by the ZIPLink F0-4AD2DA-1 wiring system. Koyo DL05/DL06 PLC expansion module, 8 analog inputs, 0-5V / 0-10V, 16-bit resolutionF0-04AD-2 $123. 00 4-channel thermocouple input module F0-04THM 4-Channel Thermocouple Input General Specifications Number of Channels 4, differential Common Mode Range-1. . Koyo DL05/DL06 PLC expansion module, 8 analog inputs, 0-5V / 0-10V, 16-bit resolutionF0-08ADH-1 $137. Add to cart More info. DL05/06 PLC Analog Module ZIPLink Selector. 0 VDC OFF Voltage Level < 2. F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. Search for Questions, Answers & Knowledge ArticlesFor business. Be the first to review this product . 0 out of 5 (0) DL05/06 analog input module; 8-channel; voltage; 16-bit; input voltage signal range(s) of 0-5 VDC. 00 8-channel analog voltage input module, high resolution ANALOG 0–10V F0-08ADH- 2 IN CH1 CH2 CH3 CH4 COM CH5 CH6 CH7 CH8 COM COM +24V 0V 24VDC Power Supply 0VDC +24VDC COM COM COM 4-wire Voltage Transmitter AC or DC CH5 3-wire Voltage + Transmitter CH3 CH1 CH8 Shield, Ch. @ 60 C 250 load 0. Title: ACFrOgD6SUhSyQ2Mt1cDDT7phpl8iFvM5qn6mnZqbPaBNWrhe9NU9HrpR_GunSGd77eYf6onXtAd_gr4. 5” (12. It’s that easy. Step 2 Locate compatible connector module type. In order to get a temperature reading you would have to use ladder logic to scale the 0-65535 reading to the temperature range of your. F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 Power Source For the latest prices, please check AutomationDirect. F0-04TRS 250mA none F0-08NA-1 5mA none F0-04AD-1 50mA none F0-04AD-2 75mA none F0-08ADH-1 25mA 25mA F0-08ADH-2 25mA 25mA F0-04DAH-1 25mA 150mA F0-08DAH-1 25mA 220mA F0-04DAH-2 25mA 30mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD 70mA none F0-04THM 30mA none D0-DEVNETS 45mA none H0-CTRIO2. The F0-08ADH-2 has jumper-selectable input ranges of either 0-5 Vdc or 0-10 Vdc. 5m, -1 = 1m, -2 = 2m1 1Note: Cable part number denotes. 8K @1 - 4VDC On Voltage Level > 10. F0-04AD-1 8 See Note 2 F0-04AD-2 8 F0-08ADH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13 F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog. 1 ms Status Indicators Module activity: one green LED Commons 2 (5 pts/common) isolated Fuse No fuse Terminal Type (Included). Specifications of the F0-08ADH-2: 8 Analog inputs; Range: 0-5V, 0-10V; 16-bit resolution; Removable terminal block;F0-08ADH-2 specifics: 8 High resolution analog inputs (voltage) Specifications Quantity per product 1 Short Description. DL05/06 PLC Fixed I/O ZIPLink SelectorThe F0-08ADH-2 has jumper selectable input ranges of either 0-5 V dc or 0-10 V dc. 0 VDC Minimum ON Current 3. 5 ms ON to OFF Response 2–8 ms, Typical 4ms OFF to ON Response 2–8 ms, Typical 4ms Commons 1 (4 points/common) D0-07CDR Output Specifications Number of Outputs 3 Output Voltage Range 6–27 VDC/6–240 VAC Output Type. F2-02DA-2L F0-08ADH-1 ZL followed by -D24 followed by -CBL40 followed by with or without, -1, -2, X, -1X,. Si el módulo F0–08ADH–2 está instalado en la ranura del PLC DL05, si se carga un valor de 8800 en V7700, configuraT1F-16DA-2 FC-T1 F0-08DAH-2 F0-08DAH-1 F0-08ADH-2 F0-08ADH-1 F0-04DAH-2 F0-04DAH-1 P3-01AC F2-8AD4DA-1 F2-8AD4DA-2 F2-CP128. Search for Questions, Answers & Knowledge ArticlesF0-04AD-2 Input Specifications Number of Channels 4, single ended (one common) Input Range 0 to 5VDC or 0 to 10VDC (jumper selectable) Resolution 12 bit (1 in 4096). F0-08ADH-2 13 F0-04DAH-1 13 F0-08DAH-1 13 F0-04DAH-2 13 F0-08DAH-2 13 F0-2AD2DA-2 8 See Note 2 F0-4AD2DA-1 8 F0-4AD2DA-2 8 F0-04RTD Matched Only F0-04THM Matched Only Note: ZIPLink Connector Modules and ZIPLink Cables specifica-tions are in the ZIPLink catalog section. Company The Company that holds the listing with UL. 5 Mbps 655 200 6557 2000 3 Mbps 327 100 3270 1000 6 Mbps 327 100 3270 1000 12 Mbps 327 100 3270 1000 Recommended Cables Siemens 6XV1 830 0AH10 Belden 3079A ERNI ERbic connectors Part No. Are you in EU? Call: +44 1782 576800. June 17, 2007 - AutomationDirect has extended its line of DirectLOGIC option modules to include 16-bit high-resolution analog modules designed for the DL05 and DL06 PLCs. LED 2 12 ECX2070-24 Buzzer 1 13 P1P1P 1 micron bag filter 102 14 Stenner check valve, Santoprene Duckbill, ferrule 1/4" 60 15 Stenner #2 tube 2 F0-08ADH-2 13 Feedthrough ZL-RTB20 ZL-D0-CBL13* F0-04DAH-1 13 Feedthrough ZL-RTB20 ZL-D0-CBL13*. Crisis lines aren’t only for people in crisis. 0 ms to 95% of full step change Crosstalk 1/2 count max (-80db)* Active Low-pass Filtering-3dB at 300Hz ZL followed by -SVC followed by CBL50 with or without, -1, -2 F2-UNICON FA-24PS T1F-16RTD T1F-16AD-1 T1F-16AD-2 T1F-16DA-1 T1F-8AD4DA-1 T1F-8AD4DA-2 ZL followed by -TSD8 followed by -24 or -120. The F0-08ADH-1 eight-channel current input module operates with a 0 to 20 mA input range. 2. Full- scale Inaccuracy (all errors included) 300 load 0. T1F-16DA-2 FC-T1 F0-08DAH-2 F0-08DAH-1 F0-08ADH-2 F0-08ADH-1 F0-04DAH-2 F0-04DAH-1 P3-01AC F2-8AD4DA-1 F2-8AD4DA-2 F2-CP128. Rev. Manufacturer : Koyo. 8–2 DL05/06 Option Modules User Manual; 7th Ed. 0以前で保存したプロジェクトファイルは、 Version 1. . 1 Analog Modules 2 Part Number F0-04AD-1 Description 4-Channel Analog Input, Current F0-04AD-2 4-Channel Analog Input, Voltage 3 F0-08ADH-1 8-Channel High-Resolution Analog Input, Current F0-08ADH-2 8-Channel High-Resolution Analog Input, Voltage 4 F0-04DAH-1 F0-04DAH-2 4-Channel High-Resolution Analog Output, Current 4-Channel. *These I/O modules have non-removable terminal blocks which can be terminated using the ZL-CBL24-N cable and the ZL-RTB20 module of the ZIPLink Connecting To An Analog Input Module - AutomationDirect. F0-08ADH-2 25mA F0-08DAH-1 25mA 220mA F0-08DAH-2 25mA 30mA F0-2AD2DA-2 50mA 30mA F0-4AD2DA-1 100mA 40mA F0-4AD2DA-2 100mA none F0-04RTD none F0-04THM 30mA none F0-CP128 150mA none H0-CTRIO(2) 250mA none H0-ECOM 250mA none H0-ECOM100 300mA none H0-PSCM 530mA none. End of Search Dialog. It's nominal output voltage is 6-48 VDC/6-208 VAC: In Stock Ships Today: F0-08ADH-1 DirectLogic 06 8-Channel Analog Input Module F0-08ADH-1 manufactured by Automation Direct: Call for Availability: F0-08ADH-2Model Number(s) Model numbers included in the listing. Input Impedance 2. LSB. 5 mA Off to On Response 2 ms, Typ. Product ID : F0-08ADH-1. ) Step 3 Select the cable length by replacing the # symbol with: Blank = 0. 8 channel analog input, voltage, 16 bit resolution. Analog Voltage Input Chapter 7 F0-04DAH-1 4-Ch. 0以前で保存したプロジェクトファイルは、 Version 1. 1 degree C/F resolution. . F0-08ADH-1 Módulo de 8 entradas 0 a 20mA ó 4 a 20mA (16 bits) F0-08ADH-2 Módulo de 8 entradas 0 a 5V / 0 a 10V (16 bits) F0-04THM Módulo de 4 entradas de termocupla resolución 0,1ºC F0-04RTD. 00. Input Impedance 2. F0-08ADH-2 $147. The F0-08ADH-1 unit is an 8-Channel Analog Current Input produced by Automation Direct. F0-08ADH-2 specifics: 8 High resolution analog inputs (voltage) Specifications Quantity per product 1 Short Description. e2-68 Programmable Controllers 1-800-633-0405 Cut PLC wiring time to minutes instead of hours The ZIPLink wiring system eliminates the normally tedious process of wiring PLC I/O to terminal blocks. Manual de módulos opcionales para DL05/DL06, 2a Ed. † Analog inputs can be used as process variables for the four (4) PIDF0-04AD-2 4 channel analog input, voltage, 12 bit resolution € 265,70 each: Add to cart More info: F0-04THM 4 channel thermocouple/mV input, 0. com. each. Model Number(s) Model numbers included in the listing. . An eight channel module, this unit converts analog voltage signals into digitally compatible signals. F0-08ADH-2 PLCs/Machine Control from FACTS ENGINEERING 2-Year Warranty, Radwell Repairs - DL05/06 ANALOG INPUT MODULE, 8-CHANNEL, VOLTAGE, 16-BIT, INPUT VOLTAGE SIGNAL RANGE(S) OF 0-5 VDC, 0-10 VDC, EXTERNAL 24 VDC REQUIRED. . PLC I/O Modules to ZIPLink Connector Modules – CLICK Note: ZIPLINk CoNNeCtor ModuLes sPeCIfICatIoNs are oN the foLLowINg Pages IN the CoMPatIbILIty MatrIx tabLes. V2001. 2 inch (5. 6. 00 Save as much as 61 % Last Value Update: 2/3/2023 Have you seen this for less?. The F0-08ADH-2 has jumper-selectable input ranges of 0 to 5 Vdc or 0 to 10 Vdc. Are you in EU? Call: +44 1782 576800. 0mS (typ. F0-08ADH-1 8-channel analog mA input module, high resolution 2-wire 4–20mA Transmitter 24VDC Power Supply 0VDC +24VDC COM COM COM 4-20mA Transmitter Shield, Ch. 1-D0-08TR 8PT RELAY OUTPUT 6-27VDC OR 6-240VAC. th. DL05/06 PLC Fixed I/O ZIPLink SelectorThe F0-08ADH-1 unit is an 8-Channel Analog Current Input produced by Automation Direct. followed by N or T followed by D or A may be followed by 1 2 may be followed by 1 D2-RSSS followed by D or A ZL-RTB50 H2-PBC H2-ECOM 2 ZL followed by -LTB16 or -LTB32 followed by -24. Modun đầu ra dòng điện F0-04DAH-1 4 kênh và F0-08DAH-1 8 kênh cung cấp dải đầu ra 4-20 mA, trong khi đó modun đầu ra F0-04DAH-2 4 kênh và F0-08DAH-2 8 kênh cung cấp dải đầu ra 0-10 Vdc. 112. Special V-memory location 7700 is used to set the data V7700 BCD setup format to either BCD or binary and to set the number of MSB LSB channels that will be active. This document also may not show all models included in the listing. The F0-08ADH-1 Analog Input module offers the following features: † The DL05 and DL06 will read all eight channels in one scan. Click Serial PLC. 5 Ohms. 2. DL05/06 PLC Fixed I/O ZIPLink Selector2–68 PLC Products 1-800-633-0405 Cut PLC wiring time to minutes instead of hours The ZIPLink wiring system eliminates the normally tedious process of wiring PLC I/O to terminal blocks. 00 2-channel analog voltage input and 2-channel analog voltage output module * One count in the specification table is equal to one. Analog Current Input Chapter 5 F0-04AD-2 4. United States. 5 mA Minimum OFF Current 0.